If you are looking for a reliable and efficient way to cool your industrial processes, you may want to consider glycol cooling. Glycol cooling is a type of refrigeration system that uses a glycol-based coolant to lower the temperature of water or air. Glycol is a non-toxic, food-grade antifreeze that can prevent freezing and corrosion in your cooling system.

How Does Glycol Cooling Work?

A glycol cooling system consists of four main components: a glycol chiller, a glycol pump, a glycol reservoir, and a heat exchanger. The glycol chiller cools the mixture of glycol and water to a desired temperature. The glycol pump is a device that circulates the glycol mixture through a closed loop of tubing or piping. The glycol reservoir is a tank that stores the glycol mixture and allows for expansion and contraction. The heat exchanger is the device that transfers heat from the process water or air to the glycol mixture.

The glycol cooling system works as follows:

  • The glycol chiller cools down the glycol mixture to a set point temperature, usually between -10°C and 10°C.
  • The glycol pump pushes the glycol mixture through the closed loop system at a constant flow rate and pressure.
  • The glycol mixture flows through the heat exchanger, where it absorbs heat from the process water or air that needs to be cooled.
  • The glycol mixture returns to the glycol reservoir, where it releases some of the heat to the ambient air.
  • The glycol mixture is then recirculated back to the glycol chiller, where the cycle repeats.
We operate seven days a week. We offer a 24/7 afterhours service and we are always available. Looking after customers is our number one concern and that’s what we have built this business on.
— Paul Renihan, Director

What Are the Benefits of Glycol Cooling?

Glycol cooling has several advantages over other types of cooling systems, such as:

  • Glycol cooling can achieve lower temperatures than water cooling, as glycol can lower the freezing point of water to as low as -60°C. This allows for more precise and consistent temperature control and cooling performance.
  • Glycol cooling can prevent freezing and corrosion in your cooling system, as glycol is an antifreeze and a corrosion inhibitor. This reduces the risk of damage and maintenance costs for your cooling system.
  • Glycol cooling can reduce energy consumption and operating costs, as glycol has a higher specific heat capacity than water. This means that glycol can absorb more heat per unit mass than water, and thus requires less cooling power and refrigerant charge.
  • Glycol cooling can improve safety and environmental compliance, as glycol is non-toxic and biodegradable. This means that glycol does not pose a health hazard or a pollution risk in case of leakage or spillage.
Only the best-performing and longest-lasting products on the market.
  • 24hr Emergency Call-Out Service
  • Quarterly & Annual Maintenance
  • F-GAS registered and certified
  • Experts in all makes and models of commercial refrigeration plant
How to contact Renihan Refrigeration:
Tel: +353 42 966 5297
Email: sales@renihanrefrigeration.com
Supply
Only the best-performing and longest-lasting products on the market with guaranteed customer satisfaction.
Install
Vastly experienced installation teams and service engineers to make sure the service is every bit as dependable as the product.
Maintain
Anything we supply, we look after it for the customer thereafter. We have a team of service technicians out on the road full-time.
Crest of the Bailieborough Shamrocks GAA gaelic football team
Renihan Refrigeration Ltd. are excited to announce our new sponsorship partnership with the Bailieborough Shamrocks GAA football team. Our new billboard will be proudly displayed at their St. Anne's Park home ground. Go n-éirí leat Shamrocks!